| ExtraNet | ExtraDownload | Sitemap | Terms & Conditions
GEA Tuchenhagen North America
Bookmark / Forward / Print

Monitoring Sensor SMW 100

for jet detection of orbital cleaning devices

...unique in its function

 

Advantages

  • Aseptic instrumentation
  • Elastomer-free sealing
  • Product wetted parts in PEEK
  • Welding sleeve system GEA Tuchenhagen

Technical Data

  • FDA / EHEDG-conform
  • Housing in 1.4305
  • Supply voltage 18 to 32 VDC
  • Power requirement < 20 mA
  • Max. output signal active 50 mA
  • Switch on delay < 0.3 s
  • Response time < 75 ms
  • Rated temperature 77 °F (25 °C)
  • Max. head interior temperature 158 °F (70 °C)
  • Ambient temperature 14 to 158 °F (-10 to 70 °C)
  • Protection class IP 65 / 67
  • Max. working pressure 145 psi (10 bar)
  • Max. 30 minute CIP/SIP cleaning 32 to 302 °F (0 to 150 °C)

Use in: water and water-based cleaning media

  • Kinematic viscosity 1.004x10 m2/s
  • Conductivity 0.05 S/m
  • Tolerance for values ± 10%